Enable the lookup-failure tuning parameter
- Last UpdatedFeb 12, 2025
- 1 minute read
- PI System
- PI Server 2024 R2
- PI Server
You must enable the lookup-failure tuning parameter on any secondary Data Archive server in a Data Archive collective that cannot resolve security mappings from the primary server. You must also enable the lookup-failure tuning parameter on the primary server in the Data Archivecollective if you define mappings valid only on secondary servers.
Note: Like any tuning parameter, collectives do not replicate this setting.
-
Click Start > All Programs > PI System > PI System Management Tools.
-
Under Collectives and Servers, select the Data Archive server where you want to enable the tuning parameter.
-
Under System Management Tools, select Operation > Tuning Parameters.
-
Click the New Parameter
button.
-
In Parameter name, type:
Base_AllowSIDLookupFailureForMapping
-
In Value, type:
1
-
Click OK.
-
Restart the server’s PI Base Subsystem.