SQL Server requirements
- Last UpdatedOct 02, 2024
- 1 minute read
PI AF collectives have these SQL Server requirements:
-
Two SQL Server instances are required, each on separate physical hardware.
-
The PI AF SQL database computers can be in a workgroup or a domain. If the PI AF SQL database computers are in a workgroup, see PI AF collectives in a domain or workgroup.
-
The primary PI AF server requires a non-Express Edition of a supported version of SQL Server. (Review the PI AF Release Notes for supported SQL Server Versions and Editions.)
-
The secondary SQL Server computer can use the SQL Express edition, with limitations. Refer to Microsoft's web site for details.
-
SQL Server Compact edition is not supported.
-
It is not necessary to have the same SQL Server edition and version for all members of a collective, but it is recommended.
-
SQL Server Agent must be running on the primary SQL Server computer.
-
SQL Server Replication must be installed on the primary SQL Server computer; it is not required on the secondary collective members. If replication is subsequently added or installed, you must restart SQL Server Agent to prevent errors.
-
When the SQL Agent is run under a domain account and the primary AF database server is 64-bit SQL Server, you must configure the C:\Program Files\Microsoft SQL Server\100\COM\ folder on the primary AF database server to allow read/write access to the SQL Agent domain account.