Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Buffering and High Availability

Status details indicate no configured subscriber

  • Last UpdatedOct 02, 2024
  • 1 minute read

This message indicates no secondary server has been configured for replication. If a secondary server has already been added to the collective, the error could indicate there is a communication problem between the primary PI AF server and secondary server, or between the secondary PI AF server and the secondary PI AF SQL database.

If the failure was due to a problem between the primary and secondary PI AF server, review the PI AF event log on the secondary server for possible causes of the error. Verify the user account used in AF Collective Manager has the proper access to the PI AF server.

If the failure was due to a problem between the secondary PI AF server and the secondary PI AF SQL database, review the PI AF event log on the secondary PI AF SQL database for possible causes of the error. Verify the user account used in the AF Collective Manager has the proper access to the PI AF SQL database.

TitleResults for “How to create a CRG?”Also Available in