LastSyncRecordID values do not match
- Last UpdatedJan 13, 2023
- 1 minute read
When you make changes at the primary server, the server queues the change to send to all secondary servers, and increments its value of LastSyncRecordID by one. When a secondary server processes a configuration change from the primary server, the secondary server increments its LastSyncRecordID value by one.
In healthy collectives, the value of LastSyncRecordID matches for all servers in the collective. If the value does not match at a secondary server and the servers are still communicating, you must Reinitialize a secondary server).