  • If the Equipment being drawn has multiple terminal strips or the number of terminals in a single terminal strip exceeds the MaxNoOfTerminals parameter, then Designer will start a new strip of terminals. If the MaxNoOfTStrips is exceeded for the current equipment, then AVEVA Instrumentation ill automatically create a new drawing sheet and continue to draw terminals/terminal strips until there are no more terminals/terminal strips for the Equipment. AVEVA Instrumentation ill continue to create new sheets if required.

  • If the Equipment being drawn has terminal strips containing more terminals in a single terminal than the MaxNoOfTerminals parameter then Designer will start a new Terminal Strip to continue until all terminals are drawn. If the MaxNoOfTStrips in not exceeded, the continuation Terminal Strip is drawn on the same drawing sheet. If the MaxNoOfTStrips is exceeded for the current equipment, then AVEVA Instrumentation will automatically create a new drawing sheet and continue to draw terminals/terminal strips until their are no more terminals.

  • ExtentsMinY controls the positioning of cables drawn to the bottom of the drawing. AVEVA Instrumentation will not draw below the ExtentsMinY.

  • Decimal numbers may be entered in the coordinate and spacing fields.