Loop Wiring Check Reports
- Last UpdatedOct 30, 2025
- 2 minute read
Loop Wiring Check Reports show a graphical 'loop diagram' type report of all wiring for current loop. The report may be printed and saved as a PDF file. This report is only available if the drawing has a valid loop number and wiring exists in the Project wiring Database (DB) for the instruments in the current loop.
These Loop Wiring Check reports are for dynamic checking of current wiring created in Wiring Manager associated with a loop's instruments.
To view a Loop Wiring Check Report:
-
Do one of the following:
-
From the Loop List select the Loop(s) to create Loop Wiring Check Reports for and click Wiring on the List Tools - Loops tab.
-
Or, in the Loop Edit window (see Edit a Loop in the Loop List), click Loop Check Report.
The report is then displayed. For example:

With the exception of the additional Export to Designer option on the File menu (see below), all menu, toolbar and other facilities are identical to those of the Tag Wiring Check Report. For details, refer to Tag Wiring Check Reports.
Notes: If the PC has a license for Instrument Wiring Manager, on any equipment tag is right-clicked on, AVEVA Instrumentation will display an option to allow access to the Instrument Wiring Manager's Terminations window, which provides drag and drop editing of cable/wire terminations, and an option to generate a termination report for the selected equipment.
If the PC has a license for Instrument Wiring Manager when any cable is right-clicked on, AVEVA Instrumentation will display an option providing access to Instrument Wiring Manager's Cable Detail window, which is used to view and edit the details of the cable.
-
Export to Designer
The is option creates a record of the diagram in the Drawing List in Instrumentation Designer and generates an AutoCAD version of the Loop diagram.
Settings for the export, such as the seed file to be used, are specified on the Export tab of the Preferences window.
Preferences
Loop Wiring Check Report preferences can be set from the Preferences window. To display this window, select Preferences from the File menu.