Cable Data Tab
- Last UpdatedNov 03, 2025
- 2 minute read
|
Class |
Used to help segregate cables in the Catalog. Valid values include Instrument, Control, Power, Thermocouple. |
|
Manufacturer/Catalog No |
These are used to define exact catalog details for purchasing. Catalog number is mandatory and must be unique in the current project. |
|
User Code |
Used to enter a user part number as an alternative to the Catalog No for reports. |
|
Cores |
The Cores section fields are used the define the cores/wires for a catalog cable. |
|
Group Type |
Used to define the core grouping (Pair = 2 cores per group, Core = 1 core per group, Triad = 3 cores per group). Cannot be changed for existing cables. |
|
No. of Cores |
Used to enter the total number of cores, pairs, triads, in this catalog cable. Note: The number of cores entered may not exceed the number of core group type markings specified in the Options window. |
|
Core Size |
Used to define the core or conductor size (for example, 1.5mm² or 12 AWG .) - do not enter the units here. |
|
Units |
Used to enter the core size units (mm² or AWG) - the units picklist is populated from unique units previously saved to the catalog. |
|
Screens/Shields |
This section is used to define the screens or shields used for signal protection for multi-core cables. |
|
OAS/Coll/SH |
This checkbox is used to specify whether or not the entire cable a single Overall Screen/Shield (Collective Outer Screen). |
|
Group/Indiv |
This checkbox is used to specify whether or not each group (that means, Pair, Triad .) has a group screen/shield (that means, Individually screened). |
|
Armoured |
This checkbox is used to specify whether or not steel wire armouring is used for this catalog cable. |
|
Earth Core |
This checkbox is used to specify whether or not an additional earth core should be included in the cable in addition to cores/shields defined. |
|
Earth Core Size |
Used to define the earth core size. |
|
Earth Core Units |
Used to define the earth core size units (mm² or AWG). |
|
Voltage Range |
Used to enter the insulation voltage range. |
|
Minimum |
Used to enter minimum voltage. |
|
Maximum |
Used to enter maximum voltage. |
|
Insulation Type |
Used to select the type of insulation. |
|
Insulation Temperature |
Used to enter the insulation temperature. |
|
Insulation Level |
Used to enter the insulation level. |
|
Color |
Used to enter the outer sheath color. |
|
Description |
Used to enter a user definable text description. |
|
Share the Catalog Cable with Electrical |
This checkbox is used to specify whether or not the catalog cable is to be shared with AVEVA Electrical. Note: Unless sharing with AVEVA Electrical is enabled for the project the checkbox will be disabled. Sharing with AVEVA Electrical may be enabled during project setup, or afterwards (using the Project tab > Edit Project option). Refer to the Installation User Guide for further information. |