Order of Accuracy
- Last UpdatedAug 24, 2022
- 1 minute read
Because the formula for the parallel thermowell is exact, it can be used to check the order of accuracy of the tapered thermowell since by making k equal to 1, the tapered thermowell becomes a parallel thermowell.
Let's take the following dimensions:
L = 300 mm
D1 = 25 mm
D2 = 25 mm
E = 200000 MPa = Pa (Typical value for steel)
r = 7800 kg/m3 (Typical value for steel)
We choose two bore diameters:
-
Do = 6.5 mm
d = 0.26
k = 1.0
Parallel Thermowell Fn: 203.3 Hz
Tapered Thermowell Fn: 204.1 Hz
-
Do = 19 mm
d = 0.76
k = 1.0
Parallel Thermowell Fn: 247.2 Hz
Tapered Thermowell Fn: 248.1 Hz
In both cases, the tapered thermowell approximate formula, when applied to a parallel thermowell, gives a natural frequency only 0.3% higher than the exact value. This gives an estimate of the order of accuracy of the formula.