  1. To edit a Fieldbus Device, do one of the following:

    • Open the Fieldbus Device Catalog and click Edit in the Records section of the Home tab.

    • Double-click on the Field Device record in the grid.

    The Fieldbus Device Definition window is displayed:

  2. Change the details of the device as required.

    For further information, refer to Global tab.

  3. To redefine the Points (Channels) or INPUT/OUTPUT Terminals, enter the number required in the appropriate box.

    Changing any of the values forces Wiring Manager to refresh the graphic representation.

  4. To edit the terminal markings, select a terminal in the graphic and enter the new value.

    Note: The <Tab> key can be used to jump between terminals.

    Important: Changing the Points (Channels) or INPUT/OUTPUT Terminals values or terminal markings changes all the devices in the project that use the current Fieldbus Device.