The flowsheet is ready to run. Observe some of the dynamic values on the graphic while the flowsheet is running.

  1. Expand the References library and select Flow Rate Indicator.

  2. Click anywhere in the Tank Level Control window near VTL1 to create a Flow Rate Indicator.

  3. You are prompted to enter the name of a flow object. In the Enter Name field, type "S1" and click OK. The new flow rate indicator for S1 appears in the graphic. The indicator initially appears with an UNKNOWN status. This is cleared as soon as the model is loaded into the database.

  4. Repeat for "S3" and "S6" (the flow leaving TTL1 and the flow leaving SRC2).

    Note: T o determine the name of a stream, leave the mouse over the line.

  5. Select Point in the References library.

  6. Click anywhere in the Tank Level Control window near PTL1 to create a point reference.

  7. You are prompted to enter the point name. In the Enter Name field type PTL1.SPEED and click OK. The new point reference for PTL1.SPEED appears in the graphic.

  8. Right-click the PTL1.SPEED point reference and select Draw Attributes.

  9. Change the Width to 100 and the Name Width to 0 and click OK.

  10. Select Point in the References library.

  11. Click anywhere in the Tank Level Control window near VTL1 to create a point reference.

  12. Right-click VTL1.L reference and select Draw Attributes.

  13. Change the Width to 130, the Name Width to 0, and the Units-of-Measure to percent.

  14. Repeat for VTL2 and VENT.

  15. Save the graphic by clicking the Save () icon, or clicking File menu and selecting Save