Replace PI Server names in templates
- Last UpdatedJan 24, 2023
- 1 minute read
- PI System
- RtReports 5.0
- Visualization
After upgrading the PI Server, you must ensure that all references to the PI Server within RtReports use the new PI Server name.
PI aliases and PI Batch aliases use the PI Server name.
-
If your RtReports report templates reference PI Module Database aliases that were located on the original PI Server, you must ensure that the PI Server name stored within the aliases now contains the new PI Server name. If this is not done, the aliases defined in the report template will not resolve correctly when run against the new PI Server.
-
If any of your report templates contains module template objects and they reference a path to a PI module which contains the PI Server name (such as "\\OldPIServer\Module1\Submodule1"), you must edit your report templates to point to the new PI Server name or the module lookup will fail when running the report template against the new PI Server.