Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Point Cloud Manager

25​.1​.0 Desktop release

  • Last UpdatedMar 14, 2025
  • 2 minute read

We are pleased to announce the release of Point Cloud Manager 25.1.0 Desktop.

This release includes the following features:

  • Point Cloud Classification

    Point cloud Manager on CONNECT will be releasing the capability to classify points using AI models later this year, and the resulting data is accessible through Point Cloud Manager 25.1 desktop application. Points will be recoloured specific to their respective classifications, and when visualised through Solid Point mode are clickable to identify sections of the classified points.

  • Floorplan resolution improvements

    Point Cloud Manager desktop application is used to position and upload pdf floorplans for CONNECT projects. This release increases the resolution, now supporting A0 size sheets with greater clarity, and providing enhanced resolution when the project through a browser on CONNECT.

  • Support for S3D 14

Bug fixes

Internal reference

Description

3691615

Z+F Flexscan rotation issue Panoramic image imported as part of the E57 file format captured using Z+F Flexscan scanners would display with an incorrection rotation of 90 degrees. This has now been resolved, and any existing data will require reconversion and generation.

371798

PTX scan export performance A bug was present in the export of data into the ptx format. This caused the time taken to complete the export to increase beyond a reasonable amount. With this fix it has now been reduced by 60%.

3607713

Chained measurements not working whilst in Cloud loaded projects.

Chained distance measurements would fail to snap to the point data.

3618856

Point cloud Manager failing to correctly load CONNECT generated projects using NavVis VLX data.

3651152

Autodesk Navisworks CAD link not working with projects containing datasets with larger than 1000 scans and issue resolved which would only install if latest version of Navisworks was installed.

3661818

E57 conversion improvements

Point cloud Manager desktop can take in E57 files from a range of other 3rd party software. This often leads to conversion issues. This fix sees improvements in handling in errors where the image is larger than expected for the scan size.

Known issues

Internal reference

Description

3367592

CAD link installation not being installed through Silent Installation mode. Currently AutoCAD and Microstation cannot be installed through Silent installation mode. This will be fixed for the next release.

3694924

Download failing for Published datasets If a project has been generated locally and published to CONNECT. When attempting to download from CONNECT it will fail at the decompression stage. This behaviour has been noted and will be fixed in the next release of the desktop application.

In This Topic
TitleResults for “How to create a CRG?”Also Available in