PI AF uses a Windows account that has no mapping
- Last UpdatedOct 04, 2024
- 1 minute read
- PI System
- PI Server 2018
- PI Server
Cause: You added PI AF access permissions for a Windows account that does not have a PI mapping. This creates a security conflict between PI MDB and PI AF.
Consequences: The corresponding module can be viewed and accessed in PI MDB only by accounts that have the necessary mappings.
Fix: On the Data Archive server, add a mapping for the Windows account. Alternatively, in PI AF, remove access permissions for that account.
Note: AF Link does not automatically pick up changes in mappings. The change does not take effect until you edit the element in some way; this triggers AF Link to update the settings in PI MDB.