Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ PI Server Installation and Configuration (PI Server 2018)

View the security synchronization report

  • Last UpdatedFeb 19, 2025
  • 1 minute read

You can view a report of security synchronization issues at any time.

  1. In PI SMT, open the AF Link tool (Operation > AF Link).

  2. Click the Details tab.

  3. At the bottom of the details pane, click the Check for Security conflicts button. If there are problems with the security synchronization, a window appears listing them.

    The report has two panes: on the left a list of Windows accounts that have security access errors; on the right the specific error for the selected Windows account. The specific error message (circled in red below) tells you what is wrong. See Possible security conflicts for more on each type of error.

    A screenshot of the Security Report dialog showing Windows account errors; red circle highlights missing AF element mapping in PI.

    Depending on the type of error, a button might appear at the bottom of the report, allowing you to fix the problem. In the example illustrated above, the fix is to create the missing mapping.

TitleResults for “How to create a CRG?”Also Available in