Mapping for multiple interfaces on the Interface node
- Last UpdatedOct 02, 2024
- 1 minute read
This deployment scenario considers an Interface node with multiple interfaces, where the interfaces do not use the same PI Identity to connect to Data Archive. In this type of scenario, different user accounts must be used for the interfaces that map to different PI Identities.
-
Create the necessary number of new Windows domain account to accommodate each different PI identity used for the mappings to access Create a new Windows domain account.
-
Map a new account to a distinct PI identity used on the Interface node. Repeat until all of the distinct PI identities are mapped.
Mapping three PI interfaces and two PI identities
Consider a deployment with three interfaces running on the Interface node: Interface1, Interface2 and Interface3. In this scenario, Interface1 and Interface2 connect with the same PI Identity: Identity12, as determined in Step 2. Interface3 connects a different PI Identity: Identity3). All three interfaces run through a Local System account, and the Interface node and PI Data Archive are on the same domain.
Mapping the interface node to Identity12 grants the appropriate permissions for Interface1 and Interface2. However, for Interface3 to continue using Identity3, a new mapping is necessary. A Windows account can only be mapped to one identity, therefore it is necessary to identify (or create) a new Window account for Interface3.
Create a new Windows domain user User3. Then, create a new PI mapping that associates the new User3 account to Identity3.