Cannot edit PI MDB
- Last UpdatedOct 04, 2024
- 1 minute read
- PI System
- PI Server 2018
- PI Server
If you cannot edit PI MDB, then you probably have one of the following problems:
-
The PI AF server is unavailable. Check your connection to the PI AF server. If AF Link cannot connect to the PI AF server, then PI MDB becomes read-only until the connection is restored.
-
AF Link is not running. If AF Link is not running, MDB is read-only. Check the PI Services tool in SMT (Operation > PI Services).
-
You are trying to make an edit that is no longer permitted in PI MDB (Learn about edits that are not allowed in PI MDB).
-
If you are trying to edit access permissions, then the PI MDB security might be out of sync with PI AF security. View the security synchronization report to identify the problem.
-
There could be a synchronization error. Check the synchronization status in the AF Link tool in SMT (Operation > AF Link).
-
MDB is not enabled. You can enable MDB by running the MDB to AF preparation wizard from the AF Link tool in SMT (Enable PI MDB).