Default raw reason code
- Last UpdatedNov 25, 2025
- 1 minute read
Enable Default Raw Reason Code to specify the code used during the initial deployment of the UCO.
Default raw reason code works as follows:
-
Each UCO requires a default reason code. The Entity Model Builder passes this code to the MES database, where it becomes the default unknown utilization reason for the entity. If the default raw reason code does not exist in the global set of reason codes, the system logs an error and marks the UCO as invalid.
-
The default raw reason code applies only after UCO deployment when the equipment status cannot be determined and all other raw reason codes evaluate to False. At run time, if all values are False, the system uses the last raw reason code with a True state, not the default raw reason code.