Switch the UCO between automatic and manual mode to record downtime events
- Last UpdatedNov 04, 2024
- 1 minute read
The Log Utilization Events attribute determines if the UCO should log raw reason code transitions to the MES database or not. When True, the UCO will log raw reason code transitions as utilization events to the MES database against the entity (that is, the parent object to the UCO). If the Log Utilization Events attribute is False, the object will continue to evaluate raw reason code transitions and update the object attributes, but it will not log utilization events to the MES database.
When the Log Utilization Events attribute transitions from True to False, the next scan of the object will not log any further raw reason code transitions to the MES database. When the Log Utilization Events attribute transitions from False to True, the next scan of the object will immediately log the current raw reason code as a utilization event to the MES database. The UCO does not require a raw reason code transition to occur; the transition of the Log Utilization Events attribute from False to True will trigger a write to the MES database.