Reset the object to clear an error condition

  • Last UpdatedNov 05, 2024
  • 1 minute read

The Reset command is used to clear the current error code and error messages, and to change the object’s status to Ready in the object context. This command applies to all the functions within the OCO object where the reset capability is available (for example, production, consumption, creating jobs, PEM, and so on).

When this command is triggered, it resets the status and error attributes that belong to the same primitive namespace as the reset attribute.

For example, a production counter is called GoodProd that has the following attributes (not all attributes are included for this example):

JobExec.JobPos0.Prod.GoodProd.ErrorCode

JobExec.JobPos0.Prod.GoodProd.ErrorMessage

JobExec.JobPos0.Prod.GoodProd.Status

JobExec.JobPos0.Prod.GoodProd.ResetCmd

When the Reset command is triggered in the GoodProd context, the error code in the JobExec.JobPos0.Prod.GoodProd.ErrorCode attribute and the error message in the JobExec.JobPos0.Prod.GoodProd.ErrorMessage attribute are cleared, and the status in the JobExec.JobPos0.Prod.GoodProd.Status attribute is set to Ready.

If the Reset command is triggered when the object context is in the Busy state, then the reset is ignored and the error code, error message, and the status is left unchanged.