Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Manufacturing Execution System 2023 R2

Standard rules and calculation types

  • Last UpdatedNov 04, 2024
  • 1 minute read

The standard rules from the MES database are described in the following table.

Rule ID

Description

0

1 point beyond/outside control limits

1

2 of 3 outside 2 standard deviations

2

3 of 7 outside 2 standard deviations

3

4 of 10 outside 2 standard deviations

4

4 of 5 outside 1 standard deviation

5

7 of 7 on one side of centerline (that is, outside 0 standard deviations)

6

8 of 8 on one side of centerline

7

8 of 8 beyond 1 standard deviation

8

9 of 9 on one side of centerline

9

10 of 11 on one side of centerline

10

12 of 14 on one side of centerline

11

6 of 6 trending up or down

12

7 of 7 trending up or down

Points beyond standard deviations are either above the positive number or below the negative number of standard deviations together. Points outside standard deviations are the violating points. They are either above the positive number of standard deviations, or below the negative number of standard deviations. It is easier to violate a Beyond rule than an Outside rule, if all the other values are the same.

The calculation for obtaining standard deviation depends on the following:

  • Chart type

  • Control limit source

  • Sigma estimation method configured for a characteristic

For more information see About Calculating Process Statistics.