Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Manufacturing Execution System 2023 R2

Change name attributes for compatibility with ISA-95

Change name attributes for compatibility with ISA-95

  • Last UpdatedNov 05, 2024
  • 1 minute read

MES in general is capable of supporting both MES attribute naming and the PEM/EOM naming, which was based on ISA-95 names. You can choose to rename the major ISA names.

Note that the naming convention used in the OCO only applies to attribute labels of the OCO, and not to the actual attributes in the PEM Instance labels in the object.

Change the name of attributes to ISA-95 names to match the PEM/EOM naming

  1. In MES Client, make a copy of the language Default (English).

  2. Edit the following strings in the new language and change the names using the Replace functionality to give new names.

    MES Name

    Attribute ID

    ISA-95 Name

    Work Order

    <1113>

    Production Request ID

    Operation

    <714>

    Process Segment ID

    Item Id

    <63>

    Material Id

    Item

    <5652>

    Material

    Operator

    <1202>

    User

    Entity

    <710>

    Equipment

  3. Save your changes.

  4. In MES Client, set the system attribute Default Language in the General Parameters section to the new language you created.

  5. Save your changes.

  6. Close and reopen the System Platform IDE so that the OCO can load the new language strings.

TitleResults for “How to create a CRG?”Also Available in