Binary attribute characteristic properties
- Last UpdatedOct 28, 2024
- 2 minute read
Binary attribute characteristics are measured by using integer numbers.
If you selected Binary attribute in the Characteristic Type menu, then provide the following information:
Sample Size Source
Specifies how the sample size is determined for the attribute. The values are as follows:
-
Fixed
Specifies the fixed sample size value in the normal sample size property.
-
Entered
Enables the option to set the minimum and maximum data entry limits for the sample size.
-
Copied from previous
Specifies the same value that is entered. At run time, the Sample Viewer .Net control resets the sample size to the value that was previously saved for the characteristic. This value uses the minimum and maximum sample size properties to set the data entry limits.
Note: The optional information for defining a binary attribute characteristic are control limits for preset values.
Control Limit Source
You can obtain control limits in the following ways:
-
Automatically Calculate from Data
Allows MES to calculate the control limits. This enables the options to enter the following:
-
Samples for Control Limit: Specifies the number of samples that are to be included in the calculation. This parameter limits the number of samples used in the calculation of control limits and process statistics, as do the parameters Cut-off time (in days) and Number of samples to consider calculating process statistics. For more information, see Control the amount of data used in process statistics calculations.
-
Samples required before Control Limits are calculated: Specifies the minimum number of samples that must exist before applying the calculated control limits to evaluate rule violations.
-
-
Compute from standard values
Specifies standard mean and standard deviation values, which are used to calculate control limits adjusted for sample size. This includes the following:
-
Standard Average Proportion: (Center Line) includes p and np charts. Enter the value as a fraction, such as 0.10 for 10%.
-
Standard Average Proportion Is Target, if selected, indicates that the target is used as the Center Line for the standard average proportion and the standard average proportion of the characteristic is not used.
-
-
Use preset values
Includes center line and upper and lower control limit values for p and np charts. Enables the user to set control limits for each chart through the Chart and its limits list. For each chart component, you must enter the lower control limit, center line, and upper control limit.
Select the Use preset values option to enter values for all the chart types.