Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Plant SCADA

[Security]DeleteWebContentProfile

  • Last UpdatedJul 19, 2023
  • 1 minute read

Use this parameter to automatically delete the application data associated with users of a Web Content control.

When a Web Content control is displayed, any user-specific data (such as cookies, storage and browsing history) is stored in the profile folder for the current Windows user (for example, C:\Users\<Windows User Name>). The following sub-directory is used:

\AppData\Local\AVEVA Plant SCADA\WebContent\Profiles\<User>\

Where <User> is the name of the user that is currently logged in to Plant SCADA runtime.

If this parameter is set to 1, the <User> folder will be deleted when:

  • The user logs out.

  • Switching to a different user account occurs.

  • If the runtime application is closed.


Allowable Values:

  • 0 -User's data is not deleted.

  • 1 - User's data is deleted.

Default Value:

0

See Also

Security Parameters

In This Topic
Related Links