Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Plant SCADA

DebugBreak

  • Last UpdatedJul 18, 2023
  • 1 minute read

Causes a breakpoint exception error to occur (error number 342). This allows programmers to trap invalid states in their Cicode. If the Cicode Editor is not running, and the Plant SCADA Runtime will start debugger on hardware errors option is set (Debug menu - Options), the Debugger will be started. When the debugger starts, the correct Cicode file, function, and line will be displayed.

Syntax

DebugBreak()

Return Value

None.

DspKernel, KerCmd, DumpKernel, TraceMsg

Example

!Check to see that rSpan is greater than zero else cause a break.
If rSpan equals 0 it would cause a Divide by Zero hardware error
anyway.

IF rSpan > 0 THEN

rCalcRate = iAmount/rSpan;

ELSE

DebugBreak();

END