Configure the Computer Role Page
- Last UpdatedApr 10, 2025
- 3 minute read
Use the Computer Role Setup page to specify the role of the computer running Plant SCADA. Select one of the options described below.
Note: To use Plant SCADA's multi-process capabilities with a Server and Control Client, networking needs to be enabled.
|
Option |
Description |
|---|---|
|
Server and Control Client |
This computer will be a standalone or networked I/O server and Control Client. This option is disabled if this computer has no Server components assigned to it to run. Selecting this option enables the Multi-Process check box. Select the Multi-Process check box to separate your client and server components into individual processes. This option can be used for distributing the components across multiple CPUs. If the Multi-Process check box is selected the [General]Multiprocess parameter in the Citect.ini file is saved with the value 1. If not selected, the parameter is saved with the value 0. If you leave the Multi-Process check box unselected, Plant SCADA will run the client and server components in one process. Note: Running Plant SCADA as a service in single process mode is not recommended. If you run Plant SCADA in this condition, the following limitations will apply:
|
|
Control Client |
This computer will only be a Control Client. This option is disabled if the computer has been assigned a server component to run. Selecting this option enables the Full License check box. Note: The Full License checkbox is only available when running the Setup Wizard in Custom Mode. Select the full server license check box if you want this Control Client to use a full (server) license, as opposed to a client license. This sets the [Client]FullLicense parameter in the Citect.ini file to 1 (the default value is 0). Generally, you would not allocate a full server license to a client as there is no difference in functionality between the two licenses. Allocate a full server license if you have insufficient client licenses available, or for some other specific need. |
|
View-only Client |
This computer will be a view-only client. This read only option is disabled if this computer has been assigned a Server component to run. |
|
HMI (Standalone, no networking) |
This computer will run as a standalone HMI setup with networking disabled. Select this option for any computers that require a dedicated HMI license from an Enterprise License Server that hosts multiple license types. If you are using Sentinel licensing, you can use a key that has networking disabled. If a full Sentinel key is plugged in, runtime will start in standalone mode with networking disabled. Select the Multi-Process check box to separate your client and server components into individual processes. This option can be used for distributing the components across multiple CPUs. If the Multi-Process check box is selected the [General]Multiprocess parameter in the Citect.ini file is saved with the value 1. If not selected, the parameter is saved with the value 0. |
Some of these options may be disabled depending on what servers have been configured to run on this computer. The Setup Wizard cross-references your computer's network identification with the network addresses configured for each server in your project configuration.
The option you select will adjust the [Client]ComputerRole parameter in the Citect.ini file.