Sprayer
- Last UpdatedFeb 02, 2024
- 4 minute read
|
Property |
Description |
|---|---|
|
Name |
Sprayer |
|
Graphical Representation |
|
|
Example Equipment Template |
Drive |
|
Associated Composite Genie |
Mining.xml |
|
Equipment.Items the Genie expects |
|
|
Equipment Parameters the Equipment Items Expect |
Equipment Configuration Parameters Equipment Configuration Parameters Equipment Configuration Parameters Equipment Configuration Parameters |
|
Associated Faceplate(s) |
Single and Multiple VSD Drive - Single Direction |
|
Equipment.Items that the Faceplate expects |
AutoCmd, ManCmd, CasCmd, FwdCmd, LocalCmd, MaintCmd, RemCmd, RevCmd, StartCmd, StopCmd, OOSCmd Fwd, Rev, Maint Stopped |
Configuration Tasks
-
Add Equipment Using Equipment Editor: Create equipment instances for the required objects, and organize the equipment in a hierarchy. Objects can be referred to by their name when you add Composite Genies to a graphics page. You can add one or more instances of an equipment to a page.
-
Configure PLC Limits with Equipment: This is an optional task that is required if you want to use PLC alarm limits instead of the standard analog alarm limits.
-
Insert a Composite Genie: Create graphics pages with instances of Composite Genies that are associated with the equipment you have defined in your project.
-
Create a New Faceplate: Add a Faceplates for the equipment to allow operators to engage with the equipment at runtime.
-
Write Cicode functions to initialize PR and OR values. Refer to the Cicode Reference documentation for more information.
Presentation Options
The following presentation options are available for this object.
|
Option |
Description |
|---|---|
|
Equipment Name |
Enter a name for the piece of equipment. You can enter a maximum of 160 characters for this option. |
|
Mining Drive Type |
From the drop down select the type of drive object to be configured. |
|
Size |
Select the size that is appropriate for the presentation of the object on the graphics page. |
|
Orientation |
Select the orientation that is appropriate for the presentation of the object on the graphics page. |
|
Display Label |
Select the location to display a label. Select None if you do not want to display a label. |
|
Label |
Enter the text that will display at the location specified in Display Label field. You can enter a maximum of 30 characters for this option. |
|
Display Alarm Indicator |
Select this option to display an alarm indicator which indicates the highest priority alarm and its state for this drive. |
|
Display Alarm Flag |
Use this setting to display an alarm flag at the selected position. Note: If you select the same position for the alarm flag and Display Status indicator (see below), they will overlap. The alarm flag will not be visible. |
|
Display Status Indicator |
Select the location to display a status indicator. Select None if you do not want to see the status indicator. For more information, see Status Indicators. |
|
Number of Equipment |
If the object represents multiple pieces of equipment, select how many pieces of equipment the object group will include. When the object displays, it will include a corresponding number of Running State Indicators. If you select 1, the Display Compact Running State option will be displayed. If more than 1 is selected the corresponding Sub Equipment #n Name fields will be displayed and the Display MEO Alarm and Display OOS options will be displayed. Note: Multiple pieces of equipment (MEO) are also known as Equipment Running State Indicators. |
|
Display Compact Running State |
Select to display a compact Equipment Running State Indicators. |
|
Display Related Equipment Alarm Indicator |
Select to display the alarm indicator which indicates the highest priority alarm and its state for every related piece of equipment in this object. |
|
Related Equipment #n Name |
Enter a name for each piece of equipment in the group. |
|
Display Control Mode |
Select this option to display a mode indicator for the object. |
|
Display OOS |
If the number of sub equipment associated with the drive object is more than 1, you can select this option to display an "Out of Service" indicator for each related equipment. |
|
Display Meter |
Select this option to display a built-in meter for the object. |
|
Display Output Bar |
Select to display an output indicator with the object. On selecting this option, the "Display Control Readback" and "Display Control Value" options are displayed. The Control Meters - Common Elements represents the actual output for the controller. |
|
Display Readback |
Select this option to display a visual marker for the readback value on the drive's output. |
|
Display Value |
Select this option to display the output value of the drive. |