Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Plant SCADA

Device Group Parameters

  • Last UpdatedAug 04, 2025
  • 2 minute read

warning2

UNINTENDED EQUIPMENT OPERATION

Do not change these protocol parameters, except on the advice of Technical Support for this product.

Failure to follow these instructions can result in death, serious injury, or equipment damage.

For the following parameters, [<unit>] represents the Citect.ini section name that is defined with the following precedence:

  • Device group: as defined in the Address field of the I/O Device. (This section is not recommended. You should choose the next section instead.)

  • Protocol.DeviceGroup: Protocol is DNPR, DeviceGroup defined in the ‘Address’ field of the I/O Device.

  • Protocol.PortName: Protocol is DNPR, PortName is defined in the ‘Port Name’ field of the Port.

  • Unit_x where x is the value in the Number field on the I/O Device. (This section is not recommended. You should choose the next section instead.)

  • Protocol.PortName.UnitName: Protocol is DNPR, PortName is defined in the ‘Port Name’ field of the Port, UnitName is defined in the ‘Unit Name’ field of the IODevice.

Example:

  • ‘Address’ field of the IODevice: 128 SITERTU

  • ‘Number’ field of the IODevice: 10

  • ‘Unit Name’ field of the IODevice: PrimaryIODev128

  • ‘Port Name’ field of the Port: PrimaryPort1

INI section names:

  • [SITERTU] (Not recommended anymore)

  • [DNPR.SITERTU]

  • [DNPR.PrimaryPort1]

  • [Unit_10] (Not recommended anymore)

  • [DNPR. PrimaryPort1. PrimaryIODev128]

These parameters are used to configure behavior that will only apply to units with the same device group, in the Citect.ini section called <unit>.

They are as follows:

Driver-specific Parameters

  • [<unit>]SCADAAddress

  • [<unit>]Timeout

  • [<unit>]Retry

  • [<unit>]TimeoutExtension

  • [<unit>]OnTimeBODeviceDefault

Peer Redundancy Parameters

  • [<unit>]ActivateIfPeerIsActiveOffline

  • [<unit>]UnitUsurpMode

  • [<unit>]SyncReplication

Event Processing Parameters

  • [<unit>]UTCTimeSync

Polling Regime Parameters

  • [<unit>]EventPollPeriod

  • [<unit>]PollPeriodOffset

  • [<unit>]EventPollRatioClass1

  • [<unit>]EventPollRatioClass2

  • [<unit>]EventPollRatioClass3

  • [<unit>]EventPollRatio

  • [<unit>]IssueIntegrityPollOnUnitRecovery

  • [<unit>]AutoUnsolicitedEnable

  • [<unit>]IntegrityPollOnUnsolicited

  • [<unit>]IPonECPMode

  • [<unit>]EnableRestartIIN

  • [<unit>]EnablePollPeriodWrites

  • [<unit>]MaxOperateDelay

Communication Parameters

  • [<unit>]MaxTimeOuts

  • [<unit>]RapidOfflineDetection

  • [<unit>]DataLinkConfirm

  • [<unit>]DataLinkNoRetriesOnControls

  • [<unit>]DataLinkRetries

  • [<unit>]DataLinkTimeOut

  • [<unit>]AppLayerTimeOut

Data Point and Cache Parameters

  • [<unit>]UseFeedBackPoll

  • [<unit>]DataLag

  • [<unit>]DataInvalidationFactor

Miscellaneous Parameters

  • [<unit>]ResponseMode