Device Group Parameters
- Last UpdatedAug 04, 2025
- 2 minute read
|
|
|
UNINTENDED EQUIPMENT OPERATION Do not change these protocol parameters, except on the advice of Technical Support for this product. Failure to follow these instructions can result in death, serious injury, or equipment damage. |
For the following parameters, [<unit>] represents the Citect.ini section name that is defined with the following precedence:
-
Device group: as defined in the Address field of the I/O Device. (This section is not recommended. You should choose the next section instead.)
-
Protocol.DeviceGroup: Protocol is DNPR, DeviceGroup defined in the ‘Address’ field of the I/O Device.
-
Protocol.PortName: Protocol is DNPR, PortName is defined in the ‘Port Name’ field of the Port.
-
Unit_x where x is the value in the Number field on the I/O Device. (This section is not recommended. You should choose the next section instead.)
-
Protocol.PortName.UnitName: Protocol is DNPR, PortName is defined in the ‘Port Name’ field of the Port, UnitName is defined in the ‘Unit Name’ field of the IODevice.
Example:
-
‘Address’ field of the IODevice: 128 SITERTU
-
‘Number’ field of the IODevice: 10
-
‘Unit Name’ field of the IODevice: PrimaryIODev128
-
‘Port Name’ field of the Port: PrimaryPort1
INI section names:
-
[SITERTU] (Not recommended anymore)
-
[DNPR.SITERTU]
-
[DNPR.PrimaryPort1]
-
[Unit_10] (Not recommended anymore)
-
[DNPR. PrimaryPort1. PrimaryIODev128]
These parameters are used to configure behavior that will only apply to units with the same device group, in the Citect.ini section called <unit>.
They are as follows:
Driver-specific Parameters
-
[<unit>]SCADAAddress
-
[<unit>]Timeout
-
[<unit>]Retry
-
[<unit>]TimeoutExtension
-
[<unit>]OnTimeBODeviceDefault
Peer Redundancy Parameters
-
[<unit>]ActivateIfPeerIsActiveOffline
-
[<unit>]UnitUsurpMode
-
[<unit>]SyncReplication
Event Processing Parameters
-
[<unit>]UTCTimeSync
Polling Regime Parameters
-
[<unit>]EventPollPeriod
-
[<unit>]PollPeriodOffset
-
[<unit>]EventPollRatioClass1
-
[<unit>]EventPollRatioClass2
-
[<unit>]EventPollRatioClass3
-
[<unit>]EventPollRatio
-
[<unit>]IssueIntegrityPollOnUnitRecovery
-
[<unit>]AutoUnsolicitedEnable
-
[<unit>]IntegrityPollOnUnsolicited
-
[<unit>]IPonECPMode
-
[<unit>]EnableRestartIIN
-
[<unit>]EnablePollPeriodWrites
-
[<unit>]MaxOperateDelay
Communication Parameters
-
[<unit>]MaxTimeOuts
-
[<unit>]RapidOfflineDetection
-
[<unit>]DataLinkConfirm
-
[<unit>]DataLinkNoRetriesOnControls
-
[<unit>]DataLinkRetries
-
[<unit>]DataLinkTimeOut
-
[<unit>]AppLayerTimeOut
Data Point and Cache Parameters
-
[<unit>]UseFeedBackPoll
-
[<unit>]DataLag
-
[<unit>]DataInvalidationFactor
Miscellaneous Parameters
-
[<unit>]ResponseMode