Motor Types symbol component
- Last UpdatedJul 29, 2024
- 3 minute read
|
|
|
|
|
|
Some equipment symbols show a motor symbol component that indicates that a motor runs pumps or other types of equipment represented by the symbol. In the case of the SA_MultiStagePump symbol, the motor symbol component can be oriented left or right based on a Wizard option selection.
There are two types of motors: Fixed and Variable. Fill animation of a Fixed motor indicates if the motor is running or not. Gray fill indicates the motor is running.
Variable motors can show other equipment states and the collective status of other pieces of equipment represented by a symbol's multiple equipment indicators.
|
|
|
|
|
|
-
When all equipment is passive or stopped, the motor symbol component does not show any fill animation.
-
When some but not all equipment is active, the pump motor show light gray fill animation.
-
When all equipment is active, the pump motor show dark gray animation.
-
When all equipment is in an interlocked safety state, the pump motor does not show any fill animation to indicate that it is stopped.
-
When all equipment is out of service, the the pump motor does not show any fill animation to indicate that it is stopped.
To configure a Fixed motor
A Fixed motor only needs a Boolean custom property that indicates if the motor is running or stopped.
|
Wizard options |
Custom properties |
|
MotorType Wizard option: Fixed | Variable |
EquipState custom property: Set to True to show that a Fixed motor is running. |
|
Orientation Wizard option - Left / Right: Right | Left |
To configure a Variable motor
To use a variable speed motor, set MotorType to Variable and set the ControllerOP Wizard option to True. The symbol shows a variable speed controller to adjust motor speed.
Other optional variable speed controller Wizard options can be configured, but only ControllerOP is required.
|
Wizard options |
Custom properties |
|
MotorType Wizard option Variable |
ControllerOP Wizard option: Set to a reference value that indicates the current output percent from a variable controller. |
|
SymbolMode Wizard option - Simple Trend: Advanced |
ControllerOPMax custom property: Set to the maximum output percentage of the variable controller. |
|
ControllerOPMin custom propertyn: Set to the minimum output percentage of the variable controller. |
|
|
ControllerOPMode Wizard option True | False |
|
|
ControllerOPCmdValue Wizard option: True | False |
|
|
ControllerOPNumericalDisplay Wizard option: True | False |