BadMax custom property

  • Last UpdatedAug 06, 2024
  • 1 minute read

BadMax sets the maximum limit on the meter scale of the SA_BulletGraph symbol in which measured values transition into a bad condition. The default value is 150.

The SA_BulletGraph symbol includes a QualitativeIndicators Wizard option with choices to set a good condition range at lower or higher measured values. When a SA_BulletGraph symbol shows good values at the higher end of its meter bar, The GoodMin and BadMax custom properties set the lower end of the good range and the higher end of the bad range respectively.

Assign values to the BadMax custom property

Application Type

Data Type

Custom Property Type

Default Value

Example Custom Property Value

ArchestrA Automation Objects

Float

Input

350

Assign an attribute or a static value.

BadMax=UDO_001.BadMax

BadMax=150

InTouch Tags

Real

Input

350

Assign an InTouch tag or a static value.

BadMax=InTouch:MaxBad

BadMax=150

The QualitativeIndicators Wizard option must be set to HigherIsGood to show the BadMax and GoodMin custom properties.

The following custom property is set with BadMin: