SpeedCtlModeCascade custom property

  • Last UpdatedAug 06, 2024
  • 1 minute read

The Boolean value of SpeedCtlModeCascade indicates Cascade operational mode of a variable control. When set to False, the variable control is not running in Cascade operational mode.

When set to True, the Control Mode Indicator shows the letter C to indicate that a variable speed controller is running in Cascade operational mode.

Assign values to the SpeedCtlModeCascade custom property

Application Type

Data Type

Custom Property Type

Default Value

Example Custom Property Values

ArchestrA Automation Objects

Boolean

Input

False

Reference to an ArchestrA object attribute or a static Boolean value.

SpeedCtlModeCascade=Pump_001.OP_CascadeMode

SpeedCtlModeCascade=False

InTouch Tags

Discrete

Input

False

Reference to a Boolean InTouch tag or a static Boolean value.

SpeedCtlModeCascade=PMP001OP_C_Mode

SpeedCtlModeCascade=False

The following Wizard options must be set to their listed values to show the SpeedCtlModeCascade custom property.

  • MotorType: Variable

  • SymbolMode: Advanced

  • SpeedController: True

  • SpeedControllerMode: True

The following custom properties must be set with ControllerOPModeCascade to set the operational mode of a variable control meter.

  • SpeedCtlModeAuto

  • SpeedCtlModeManual

  • SpeedCtlModeNormal