Configure a basic SA_GainLossChart symbol using InTouch tags
- Last UpdatedJul 30, 2024
- 2 minute read
The basic configuration of a SA_GainLossChart_Pairs symbol shows a chart consisting of 10 chart bars oriented vertically. Each chart bar contains paired measured values that represent gains and losses. The symbol shows a chart heading and descriptions of the horizontal and vertical chart axes.

For the sake of simplicity, this procedure shows how to configure a simple chart symbol consisting of only two gain/loss chart bars.
Note: Chart bars that show gain values have a white background. If necessary, place a non-white background behind the symbol to provide contrast to see the chart bars.
Prerequisites
This procedure explains how to configure a basic symbol using references to InTouch tags
-
To follow the steps of this procedure, create four InTouch Memory Real tags.
-
Create an InTouch application with a window to verify that the symbol has been configured correctly.
To configure a basic SA_GainLossChart symbol using InTouch tags
-
Drag and drop the symbol in a WindowMaker window.
-
Double-click on the symbol to show the Edit Symbol Properties dialog box.
-
Click the Wizard options tab and set NumberOfBars to Two.
-
Click the Custom Properties tab to show the default custom properties.
-
Assign InTouch tags to the Bar01Gain and Bar01Loss custom properties.
-
Select Bar01Gain from the list of custom properties.
-
Click the Browse Galaxy button to the right of the Default Value field to show the Select Tag dialog box.
-
Assign an InTouch tag as the reference value of the Bar01Gain custom property.
-
Repeat steps a-c to assign another InTouch tag as the reference value of the Bar01Loss custom property.
-
-
Repeat steps 5a through 5d for the Bar02Gain and Bar02Loss custom properties.
-
Save your changes.
-
Run the application containing the SA_GainLossChart symbol in WindowViewer to verify that your configuration changes are correct.