Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Situational Awareness Library

ValveModeCascade custom property

  • Last UpdatedAug 06, 2024
  • 1 minute read

The Boolean value of ValveModeCascade indicates Cascade operational mode of a valve.

When set to True, the Control Mode Indicator shows the letter C to indicate that a valve is running in Cascade operational mode.

Assign values to the ValveModeCascade custom property

Application Type

Data Type

Custom Property Type

Default Value

Example Custom Property Values

ArchestrA Automation Objects

Boolean

Input

False

Reference to an attribute or a static Boolean value.

ValveModeCascade=Pump_001.OP_CascadeMode

ValveModeCascade=False

InTouch Tags

Discrete

Input

False

Reference to a Boolean InTouch tag or a static Boolean value.

ValveModeCascade=PMP001OP_C_Mode

ValveModeCascade=False

The following Wizard options must be set to their listed values to show the ValveModeCascade custom property.

  • SymbolMode: Advanced

  • ControllerModeIndicator: True

The following custom properties must be set with ValveModeCascade to set the operational mode of a variable control meter.

  • ValveModeAuto

  • ValveModeManual

  • ValveModeNormal

In This Topic
TitleResults for “How to create a CRG?”Also Available in