ValveModeAuto custom property

  • Last UpdatedAug 06, 2024
  • 1 minute read

Boolean value that Indicates a valve is operating under automatic (A) operation control. The default value is False.

When set to True, the Control Mode icon shows the character A next to the symbol.

Assign values to the ValveModeAuto custom property

Application Type

Data Type

Custom Property Type

Default Value

Example Custom Property Values

ArchestrA Automation Object

Boolean

Input

False

Set to an attribute.

ValveModeAuto=ODA1.AutoMode

InTouch Tags

Discrete

Input

False

Set to a InTouch tag.

ValveModeAuto=AutoMode

The following Wizard options must be set to their listed values to show the ValveModeAuto custom property.

  • SymbolMode: Advanced

  • ControlModeIndicator: True

The following custom properties must be assigned reference values to define the possible operational modes of a a valve.

  • ValveModeAuto

  • ValveModeCascade

  • ValveModeManual

  • ValveModeNormal