Configure a basic SA_ColumnChart symbol using ArchestrA attributes
- Last UpdatedJul 30, 2024
- 2 minute read
The basic configuration of a SA_ColumnChart symbol shows a chart consisting of 10 chart bars oriented vertically. Each chart bar is assigned an individual measured value. The symbol shows a chart heading and description, descriptions for the horizontal and vertical chart axes, measured value labels, and numeric measured values.
For the sake of simplicity, this procedure shows how to configure a simple chart symbol consisting of only two chart bars.

Prerequisites
This procedure explains how to configure a basic symbol using references to ArchestrA attributes.
-
To follow the steps of this procedure, create two ArchestrA objects that meet the following requirements:
-
Includes an Analog PV field attribute
-
Enable I/O scaling with the input clamped to the EU range
-
Enable limit alarms with limits specified for HiHi, Hi, Lo, and LoLo alarms
-
-
Create an InTouch application with a window to verify that the symbol has been configured correctly.
To configure a basic SA_ColumnChart symbol
-
Embed the symbol in another symbol in the Industrial Graphic Editor.
-
Select the symbol.
-
Show the symbol's list of Wizard options by at the right of the Industrial Graphic Editor window.
-
Set NumberOfBars to Two.
-
Right-click on the symbol and select Custom Properties to show the Custom Properties dialog box.
-
Assign reference values to the BarXX custom properties and click OK.
-
Select the Bar01 custom property from the list and click the Galaxy Browser button to the right of the Default Value field.
-
Click the Attribute Browser tab and select an attribute from the list to assign to the custom property.
-
Repeat these steps to assign an attribute to Bar02.
-
-
If you want, assign optional string values to the symbol's labels.
-
Right-click on the symbol, select Substitute, and then select Substitute Strings.
-
Enter string values into the fields of the Substitute Strings dialog box that match the default strings shown for the symbol and click OK.
-
-
Save the symbol and check it in.
-
Deploy the Galaxy containing the object with attributes that are used as reference values of the custom properties.
-
Double-click an instance of InTouch ViewApp to start WindowMaker.
-
Create a new InTouch window and embed the symbol containing the symbol.
-
Run the application in WindowViewer to verify that your basic symbol configuration works correctly.