Add Lists of Components with Multi-Line Designators
- Last UpdatedMar 14, 2024
- 3 minute read
This procedure is used to add lists of components to drawings using multi-line designators.
The content of a list is derived from a query selected during the procedure. The queries themselves are defined using the custom query functionality provided by AVEVA P&ID Reports (refer to AVEVA P&ID Reports documentation for details).
Example

Associated Project Configuration Options
-
Settings that control the layout and other details related to the insertion of multi-line designators are set in the Multi-Line Designator Settings section of the Miscellaneous – Settings Sub-Category of the AVEVA P&ID Project Administration program.
-
The Designator Settings section in the Miscellaneous - Settings Sub-Category is used to set general designator options.
-
Multi-line designators use the XMV Multi-line Designator and XMH Multi-Line Designator Header label types, as defined in the Label Types Configuration Category of the AVEVA P&ID Project Administration program.
Procedure
-
Start the procedure by selecting the Add Designator option in the P&ID Reports group of the Manage tab. The Insert Multiline Designators dialog is then displayed:

-
Select the required query from the Select Item Type drop down list. This list includes all custom P&ID Reports queries prefixed with <EXCEL_TABLE>. For example, for equipment lists, select EXCEL_TABLE_EQULIST.
If such queries are not present then actual tables will be used, for example, <EQULIST>.
-
Enter the distance between rows in the Distance between rows field.
-
If required, check the Place Designator Vertically checkbox.
Note: If vertical designators are defined, based on the angle of the designator, the user will have to use X or Y offset to account for the placement of the designators before refreshing.
-
Select which designators/data from the selected table are required on the drawing by checking the appropriate checkboxes. Check the Select All checkbox to check all the designator checkboxes.
-
If required, a fixed offset distance between the designators can be used. To apply this, check the Fix position of designators checkbox and enter the distance in the Offset field.
-
Select OK.
-
Place the first designator on the drawing manually. The application will then ask for the designator’s required rotation.
-
If Fix position of designators checkbox was checked, the remaining designators will be placed automatically, otherwise continue to place designators as prompted.
-
When all designators have been placed, select the Refresh Designators option in the P&ID Reports group of the Manage tab. The designators will then be populated with the appropriate item data as returned by the query for the selected designators.
Note: Multi-line designator component lists will be updated ONLY when user selects the Refresh Designators option and not when a drawing is opened or Synchronized.
Note: When existing designators (for example, those previously placed) are being refreshed, those designators with values that have changed since the last refresh are highlighted by being displayed in a different colour.: