Connect Pipes located at different Design Areas stored in Different Databases
- Last UpdatedMar 14, 2024
- 2 minute read
The example displays pipe 90015 which starts on drawing 905675 from pipe 90003. Pipe 90015 is associated with design area 20, it continues to drawing 905679 which is associated with area 60.

On drawing 905679 the pipe connects to header pipe 90017.

To connect both pipe segments, reporting the source and destination across both design area 20 and 60 databases, edit both page connectors and add a link to the source and destination databases, then save both drawings.
The example displays the off page connector properties with the Target Database attribute linked to the database associated with design area 60.

The example displays the off page connector properties with the Target Database attribute linked to the database associated with design area 20.

Synchronize and consolidate both databases linked with design areas 20 and 60.

Pipeline 905675 will display on the line list for both areas with the respective source and destination.