Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ P&ID

Insert Equipment

  • Last UpdatedMar 14, 2024
  • 2 minute read

General points on the procedure are given in Insert Symbols.

Equipment items are positioned stand-alone. All equipment items can be configured so that they can be re-sized, using the Symbols Configuration Category of the AVEVA P&ID Project Administration program.

Vessels have the EQV item type and all other equipment is classified as EQU.

Note: The procedure for inserting inline equipment is identical to that for inserting inline fittings. Refer to Insert Inline Fittings.

Note: Sub-equipment is discussed in Insert Sub-Equipment (for example, Electrical Equipment). Equipment Data Location is discussed in Insert Miscellaneous Symbols.

For details of the use of this command in the context of drawing P&IDs, see Insert Symbols.

Note: Instead of inserting symbols, new symbols can be placed on the drawing by copying and pasting existing symbols. Refer to Copy Drawing Objects and Labels.

Example

Embedded Image (65% Scaling) (LIVE)

Associated Project Configuration Options

Equipment may be set either to be fixed size or re-sizable upon insertion. This setting is made in the Symbols Configuration Category of the AVEVA P&ID Project Administration program. If an item is set to be re-sizable, a prompt will be received upon insertion for size in both the X and Y directions after the item is inserted.

Procedure

  1. Select an equipment symbol by using the Symbol Explorer.

  2. After the symbol has been selected a 'ghosted' image of the equipment will appear on the cross hairs. The Command prompt will display:

    Indicate point for <chosen equipment>:

    Pick the desired position.

  3. If the item type is set to be re-sizable, the Command prompt will then display:

    X scale factor <1>:

    Enter an X scale factor via the keyboard if required.

  4. The Command prompt will then display:

    Y scale factor <default X>:

    The Y scale defaults to the X scale automatically unless another value is entered.

  5. The Command prompt will then display:

    Rotation angle <0.000>:

    Enter a rotation angle if required.

    Note: You can 'show' the rotation angle by picking two points. The item is then placed.

  6. The Command prompt will then display:

    Indicate point for <chosen equipment>:

    Place another item, or select Cancel from The Drawing Page menu or press Ctrl-C to end the command.

If auto-labelling is on, the Label Equipment (with or without Trim) procedure will then start automatically.

In This Topic
Related Links