Apply Filters to Pipe Property Lists of Values
- Last UpdatedMar 14, 2024
- 1 minute read
Using the filter value for a drawing, lists of values for pipe properties (Spec, Size, Fluid/Service and Area) may be created that are only available for that specific drawing (and other drawings that share that value), and which must be used when specifying pipe properties for that drawing.
In other words, only those lists of values will be available when selecting pipe properties for that drawing, and the "normal" list of values for pipe properties, and other drawing-specific pipe property lists of values will not be available.
The lists of values are set up using the List of Values Configuration Category of the AVEVA P&ID Administration program. The names of these lists of values must be in following format:
USERLOV_<PropertyName><FilterValue>
For example:
USERLOV_SPEC722
USERLOV_METSIZES722 (for Metric projects)
USERLOV_IMPSIZES722 (for Imperial projects)
USERLOV_SERV722
USERLOV_AREA722