Changes to drawings resulting from the Reducer project configuration settings being changed are not automatically implemented when project drawings are loaded. The user must trigger these changes "manually" in each drawing after it has loaded using this procedure.

Note: As an alternative to the procedure below, if only a single label is to be updated, opening and closing the Properties Dialogs of that reducer will update its label format.

Associated Project Configuration Options

This procedure is used to implement changes made to the Reducer settings in the Reducer Configuration Category of the AVEVA P&ID Project Administration program.

Procedure

  1. Start the procedure by selecting the Update Reducer Tag option in the Project Configuration group of the Utilities tab.

  2. The command prompt will display:

    Pick Reducer for reformatting the tags:

    Select the reducers the tags of which are to be updated. When all the required reducers have been selected, press Enter.

    If all reducer tags on the drawing are to be updated, enter all at the command prompt and press Enter. It is recommended that a Zoom Extents is performed before proceeding with this option.

  3. The command prompt will display the number of selected reducers (for example):

    5 found

    The labels of the selected reducers are then updated. If many reducers have been selected, this may take a few moments.