Disconnect Pipes from Nozzles and Equipment
- Last UpdatedJan 30, 2025
- 1 minute read
Nozzles and pipes in the same pipe group may inherit sizes from each other. If this is not required for a particular pipe and nozzle, this procedure can be used to disconnect a pipe from a nozzle (or from equipment), so that they are no longer in the same pipe group.
To check whether a nozzle is part of a pipe group, hover the cursor over the nozzle on the drawing so that it becomes highlighted. If the pipe and its components also become highlighted, the nozzle is part of the pipe group.
Note: A facility is also available to add nozzles and equipment to a pipe group. Refer to Connect Pipes to Nozzles and Equipment.
For details of the use of this procedure in the context of drawing P&IDs, refer to Draw Pipes and Process Links and Label Nozzles.
Note: Not applicable to drain pipes.
Associated Project Configuration Options
The Cascade Nozzle to Pipe checkbox in the Nozzles – Settings Sub-Category of the AVEVA P&ID Project Administration program controls whether or not sizes are cascaded between nozzles and pipes.
Procedure
-
Start the procedure by selecting the Disconnect option in the Modify group of the Home tab.
-
The Command prompt will display:
Pick pipe group and equipment to disconnect:
Select the nozzle or equipment to remove from the pipe group.
The nozzle or equipment is then removed from the pipe group.