Loads Tab (Winding Tab - Transformers)
- Last UpdatedJul 25, 2025
- 2 minute read
This tab is used allocate loads to a transformer winding.

Note:
No fields or data will be displayed on this tab until the supply is saved.
To assign a load to the winding:
-
Click the Assign button (the button will be disabled if a load is already assigned).
-
The Assign Load window is then displayed:

-
Select one of the transformer’s output voltages from the Output Voltage list. The output voltages for a transformer are viewed and specified using the Output Voltages tab.
-
The windows then lists the available loads (including supplies that may be loads) with voltages matching the selected output voltage. Select the required load by double-clicking on it or clicking on it and clicking Assign.
-
If, with the addition of the selected load, the sum of the rated power of the loads assigned to the supply would be greater than the supplies rated power, a warning message is displayed. For example:

-
Click Yes to assign the load anyway or No to cancel.
-
The load is then listed in the tab.
To un-assign the load, click the Un-Assign button. A message is displayed requesting that the un-assignment be confirmed. Click Yes to continue.