Add Circuits and Phase Ways - Circuit Number / Phase Id Circuit Identification Method

Add Circuits and Phase Ways - Circuit Number / Phase Id Circuit Identification Method

  • Last UpdatedAug 07, 2025
  • 2 minute read

If the Circuit Number / Phase Id circuit identification method is in use for the distribution board, the following buttons are provided:

To add a circuit:

  1. Click either Add 1 Phase Way, Add 2 Phase Way, Add 2 Phase Way + N, Add 3 Phase Way or Add 3 Phase Way + N as required.

    Note:
    The Add 2 Phase Way + N and Add 3 Phase Way + N buttons are only available if the Has Neutral checkbox on the Detail tab is checked.

  2. If Add 1 Phase Way, Add 3 Phase Way or Add 3 Phase Way + N is clicked, the selected phase way and circuits are then added to the viewer. If Add 2 Phase Way or Add 2 Phase Way + N is clicked, the Options window is displayed:

  3. Select the required option. The 2 phase way and circuits are then added to the viewer, plus a neutral termination if that option was selected.

  4. Continue to add phase ways and circuits as described above until all required circuits have been added. For example:

  5. Use the Undo and Redo buttons to remove or re-add circuits.

  6. Once all required circuits have been added, click Save.

  7. When the viewer is saved, a circuit breaker with default details is automatically created for each phase way. The rated current (by default, 0A) of these devices is displayed for each phase way in the viewer:

The current and other circuit breaker details are edited using the Circuit Breaker Detail window (refer to View/Edit Circuit Breaker Details).