Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Electrical

AVEVA Asset Information Management Export Configuration

AVEVA Asset Information Management Export Configuration

  • Last UpdatedAug 05, 2025
  • 3 minute read

Before files can be exported for AVEVA AIM, the export must be configured:

  1. From the Project tab, click Setup, then Publish to AIM Configuration. The AIM Export Configuration window is then displayed.

  2. AVEVA Electrical data of various types and from different sources can be exported to AVEVA AIM, for example loads data or data from reports. From the Name field, select the type of data export to AVEVA AIM to be configured.

  3. If a log file is to be generated for the export type, check the Log Enabled checkbox.

  4. The Log File field will then become enabled. In the field, specify the file name and the location of the log file (a .txt file). Click the button to browse for the required folder.

  5. In the Staging Area field, specify the top level folder into which files are to be exported. Click the button to browse for the required folder.

  6. If the Create Trigger File checkbox is checked, a trigger.start file (an empty text file) is created in the staging area folder for each file type. The purpose of the trigger.start file is to trigger the AVEVA AIM Portal’s import controller to automatically process all the files that reside in the same folder.

  7. If, for every object being exported, a separate output file is to be generated, check the Output File Per Object checkbox.

  8. To select mapping files for the export of data and specify other settings, click Settings. The Non-CAD Mapping Configuration window is then displayed.

    The mappings between AVEVA Electrical data and AVEVA AIM Portal format data are stored in XML files, one for each of the types of mapping:

  9. Click the appropriate button to browse for the required mapping file.

  10. Click the open file button to open the selected file. It will open in the default text editor, for example Notepad.

    If no file is specified in the field, a new, blank .txt file is opened. If a file is specified that does not exist, the user will be asked if they want to create that file at the specified location. If the users clicks Yes, a new blank .txt file is created and opened for editing.

  11. To populate the fields with the default mapping files supplied with AVEVA Electrical, click Copy Sample Files.

TitleResults for “How to create a CRG?”Also Available in