Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Electrical

Change Cable Core Markings

  • Last UpdatedFeb 11, 2022
  • 2 minute read

To enter or edit the cable core markings of a catalogue cable, select the catalogue record from the Cable Catalogue, then click Edit in the Records section of the Home tab, or double-click on the catalogue cable record.

Note:
Changing the core markings of a catalogue cable will result in the core markings for every cable in the project that is based on this catalogue cable being changed as well.

Only data in the Marking and CoreType columns may be edited.

Note:
The core type is used by Electrical Wiring Manager when creating reports and terminations OAS = Overall screen, S = screen/shield, E = Earth wire, C = Core (i.e. normal wire - any core that is not a shield or earth wire).

Important:
Electrical Wiring Manager uses a relational database to store information then any change to core markings for a catalogue cable effect all project cables that use this catalogue cable. For example, changing marking '1W' to '1WH' will change the first core in project cable instances that use this catalogue cable for every cable in the project.

Note:
The default cable core colours/markings and core group type markings are set for the project using the Cable Schedule Options window. These preferences are applied to new catalogue cable creation only.

Related Links
TitleResults for “How to create a CRG?”Also Available in