Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Electrical

Equipment Pop-up Menu Commands

  • Last UpdatedJul 29, 2025
  • 3 minute read

As explained above, the right-click (on a node) pop-up menu is context sensitive. The menu will display a selection of the following commands:

Edit Detail

Displays a window for editing the data of the item represented by the selected node. Refer to Edit and Rename Items in the Equipment View.

Edit Terminations

Displays the Terminations window. Refer to Terminations User Interface.

Various Add ....
commands:

Clicking on an Add... command will display a window for adding equipment to the Electrical Wiring Manager database. The item to be added is created at the equipment node (or Area node if an Area node is selected etc.) selected when the pop-up menu was opened (the node that was right-clicked on). Refer to Refer to Add Area, Buildings, Equipment Rooms and Vendor Packages, Add Equipment, Add Field Devices and Terminal Strips, Earth Bars, Din Rails, Devices, I/O Modules and Group Labels.

Cut

Allows the current selected equipment node to be moved. Select the node to move, then 'Cut', then select a new parent node then 'Paste'. Only applicable to devices and "internal components", e.g. DIN Rails, terminal strips, earth bars, devices etc. (but not compartments and their components).

Paste

Used to complete a copy or cut.

Note:
Electrical Wiring Manager will only allow copying/moving to a valid parent node based on equipment type. For example a PLC Cabinet cannot be pasted (copied or moved) to a Terminal Strip or a DIN Rail copied to an Plant Area or a PLC Cabinet to a PLC Cabinet etc.

Copy

Used to copy the currently selected equipment node. Select the node to copy, right-click then select Copy, then select the new parent node, then right-click and select Paste from the menu. Only applicable to devices and "internal components", e.g. DIN Rails, terminal strips, earth bars, devices etc. (but not compartments and their components).

Copy (with 'From' cables)

Only applicable to PLCs and Local Control Stations. This menu option only appears if the node selected has 'From' cables (i.e. cables in the cable schedule leading from this equipment). Select the node to copy, right-click then select Copy (with 'From' cables), then select the new parent node (e.g. a Plant Area, Building or Room) then right-click and select the Paste command.

This command is the same as above Copy command but also copies any cables and terminates the new cables exactly as the cables are terminated in the original 'source' equipment selected. The Copy Equipment with Cables window is displayed, used to assign new Cable Numbers to the copied cables. See Copy Equipment.

Delete

Used to delete the item (node).

Refresh

Refreshes the view and closes all the sub-menus

Find

Displays a window used to enter a Tag Number and search for it within the Equipment View.

Collapse All

Closes all the tree "branches".

Also available on the Tools - Equipment Tree tab.

Expand Selected

Opens all the sub-"branches" for the selected item.

Also available on the Tools - Equipment Tree tab.

Print Preview Terminations

Displays Termination Reports for the currently selected equipment node as a Print Preview (if the node represents Equipment).

Ferrule No Report

Displays a window that shows all wire ferrule numbers for each terminal strip/device in the selected equipment allowing for easy definition of ferrule/wire numbers.

Auto Ferrule Selected Equipment

Used to automatically add ferrule numbers to the wire ends connected to the equipment in accordance with pre-defined numbering rules. Accesses a sub-menu from where the left, right or both sides of the equipment can be selected for numbering. Refer to Updating Ferrule Nos by Ferrule Rules for further information.

Create Wiring

Used to create the wiring for equipment. Refer to Create Wiring for further information.

Wiring Check Report

Opens a report that displays the wiring for equipment that have had wiring created for them. Refer to Field Device Wiring Reports for further information.

Attached Documents

Displays the Attached Documents window. Refer to Attachments (External Documents) for further information.

Note:
Electrical Wiring Manager is configured to allow only certain types of Equipment objects to be 'external' or 'internal' to other equipment types. For example a Cabinet cannot be created or pasted (copied or moved) to a Terminal Strip or a DIN Rail created or copied or moved to a Plant Area etc.

Note:
Equipment can also be accessed from Electrical Wiring Manager's Equipment List grid. The Equipment List support the Grid Manager, filtering etc.

Related Links
TitleResults for “How to create a CRG?”Also Available in