Equipment Pop-up Menu Commands
- Last UpdatedJul 29, 2025
- 3 minute read
As explained above, the right-click (on a node) pop-up menu is context sensitive. The menu will display a selection of the following commands:
|
Edit Detail |
Displays a window for editing the data of the item represented by the selected node. Refer to Edit and Rename Items in the Equipment View. |
|
Edit Terminations |
Displays the Terminations window. Refer to Terminations User Interface. |
|
Various Add .... |
Clicking on an Add... command will display a window for adding equipment to the Electrical Wiring Manager database. The item to be added is created at the equipment node (or Area node if an Area node is selected etc.) selected when the pop-up menu was opened (the node that was right-clicked on). Refer to Refer to Add Area, Buildings, Equipment Rooms and Vendor Packages, Add Equipment, Add Field Devices and Terminal Strips, Earth Bars, Din Rails, Devices, I/O Modules and Group Labels. |
|
Cut |
Allows the current selected equipment node to be moved. Select the node to move, then 'Cut', then select a new parent node then 'Paste'. Only applicable to devices and "internal components", e.g. DIN Rails, terminal strips, earth bars, devices etc. (but not compartments and their components). |
|
Paste |
Used to complete a copy or cut. |
|
Note: |
|
|
Copy |
Used to copy the currently selected equipment node. Select the node to copy, right-click then select Copy, then select the new parent node, then right-click and select Paste from the menu. Only applicable to devices and "internal components", e.g. DIN Rails, terminal strips, earth bars, devices etc. (but not compartments and their components). |
|
Copy (with 'From' cables) |
Only applicable to PLCs and Local Control Stations. This menu option only appears if the node selected has 'From' cables (i.e. cables in the cable schedule leading from this equipment). Select the node to copy, right-click then select Copy (with 'From' cables), then select the new parent node (e.g. a Plant Area, Building or Room) then right-click and select the Paste command. This command is the same as above Copy command but also copies any cables and terminates the new cables exactly as the cables are terminated in the original 'source' equipment selected. The Copy Equipment with Cables window is displayed, used to assign new Cable Numbers to the copied cables. See Copy Equipment. |
|
Delete |
Used to delete the item (node). |
|
Refresh |
Refreshes the view and closes all the sub-menus |
|
Find |
Displays a window used to enter a Tag Number and search for it within the Equipment View. |
|
Collapse All |
Closes all the tree "branches". Also available on the Tools - Equipment Tree tab. |
|
Expand Selected |
Opens all the sub-"branches" for the selected item. Also available on the Tools - Equipment Tree tab. |
|
Print Preview Terminations |
Displays Termination Reports for the currently selected equipment node as a Print Preview (if the node represents Equipment). |
|
Ferrule No Report |
Displays a window that shows all wire ferrule numbers for each terminal strip/device in the selected equipment allowing for easy definition of ferrule/wire numbers. |
|
Auto Ferrule Selected Equipment |
Used to automatically add ferrule numbers to the wire ends connected to the equipment in accordance with pre-defined numbering rules. Accesses a sub-menu from where the left, right or both sides of the equipment can be selected for numbering. Refer to Updating Ferrule Nos by Ferrule Rules for further information. |
|
Create Wiring |
Used to create the wiring for equipment. Refer to Create Wiring for further information. |
|
Wiring Check Report |
Opens a report that displays the wiring for equipment that have had wiring created for them. Refer to Field Device Wiring Reports for further information. |
|
Attached Documents |
Displays the Attached Documents window. Refer to Attachments (External Documents) for further information. |
Note:
Electrical Wiring Manager is configured to allow only certain types of Equipment objects to be 'external' or
'internal' to other equipment types. For example a Cabinet cannot be created or pasted
(copied or moved) to a Terminal Strip or a DIN Rail created or copied or moved to
a Plant Area etc.
Note:
Equipment can also be accessed from Electrical Wiring Manager's Equipment List grid. The Equipment List support the Grid Manager, filtering etc.