AVEVA™ Electrical

Cable Termination Options

  • Last UpdatedAug 04, 2025
  • 1 minute read

When terminating a cable from the Terminations window a user will be prompted to select a termination options from the Connect Options window:

Match Signal Nos

Attempts to match the signal number on opposite side of terminal strip with any signal numbers found in the cable's Cores to Terminate list. If a match is found, that core/wire will be terminated at the terminal with the matching signal number.

Don't Match Signal Nos

Wiring Manager looks for first available terminal and connects the first core in core list to the first available terminal found. It then looks for the next available terminal and terminates the next core.

Terminate Shields/Screens/Earth

When checked, screens/shields/earth will be terminated. When unchecked, they will be left disconnected.

Skip Shield/Screen/Earth Terminals

If the Terminate Shields/Screens/Earth option is unchecked, users are given the option to skip a terminal where a shield/screen would have been terminated, or where the other side of a terminal has a screen/shield terminated.

Note:
In all cases, signal/wire numbers will be updated using Electrical Wiring Manager's Signal Number Inheritance feature. If users chose not to match signal numbers, and signal numbers on a available terminal do not match, users are warned of this, but the termination still takes place.