Add Cables to the Catalogue

  • Last UpdatedAug 01, 2025
  • 4 minute read

To add a new Cable to the project Cable Catalogue, open the Cable Catalogue grid and click New from the Records section of the Home tab.

Note:
Electrical Wiring Manager also provides facilities for importing of Catalogue Cables from another project. Refer to Importing Catalogue Items from another Project.

The Catalogue Cable Details window is then displayed:

Check the Allow use on Project checkbox if the catalogue cable is to be available for use in the project, so that listed in the Cable Schedule etc. The checkbox is checked by default.

Note:
Only those cables with their Allow use on Project checkbox checked will be available for use when working in the project Cable Schedule. Although the cable catalogue can hold thousands of standard cables from various manufacturers, 'Allow' filters only specific cables for use on the project.

Cable Data Fields

Class

Used to help segregate cables in the Catalogue. Valid values include Instrument, Control, Power, Thermocouple etc.

Manufacturer/Catalogue No

These are used to define exact catalogue details for purchasing. Catalogue number is mandatory and must be unique in the current project.

User Code

Used to enter a user part number as an alternative to the Catalogue No for reports etc.

Cores

The Cores section fields are used the define the cores/wires for a catalogue cable.

Group Type

Used to define the core grouping (Pair = 2 cores per group, Core = 1 core per group, Triad = 3 cores per group etc.).

Cannot be changed for existing cables.

No. of Cores

Used to enter the total number of cores, pairs, triads etc. in this catalogue cable.

Note:
The number of cores entered may not exceed the number of core group type markings specified in the Options window.

Core Size

Used to define the core or conductor size (e.g. 1.5mm² or 12 AWG etc.) - do not enter the units here.

Units

Used to enter the core size units (mm² or AWG) - the units picklist is populated from unique units previously saved to the catalogue.

Screens/Shields

This section is used to define the screens or shields used for signal protection for multi-core cables.

OAS/Coll/SH

This checkbox is used to specify whether or not the entire cable has a single Overall Screen/Shield (Collective Outer Screen).

Group/Indiv

This checkbox is used to specify whether or not each group (i.e. Pair, Triad etc.) has a group screen/shield (i.e. Individually screened).

Armoured

This checkbox is used to specify whether or not steel wire armouring is used for this catalogue cable.

Earth Core

This checkbox is used to specify whether or not an additional earth core should be included in the cable in addition to cores/shields defined.

Earth Core Size

Used to define the earth core size.

Earth Core Units

Used to define the earth core size units (mm² or AWG).

Voltage Range

Used to enter the insulation voltage range.

Minimum

Used to enter minimum voltage.

Maximum

Used to enter maximum voltage.

Insulation Type

Used to select the type of insulation.

Insulation Temperature

Used to enter the insulation temperature.

Insulation Level

Used to enter the insulation level.

Colour

Used to enter the outer sheath colour.

Description

Used to enter a user definable text description.

Share the

Catalogue Cable with Instrumentation

This checkbox is used to specify whether or not the catalogue cable is to be shared with AVEVA Instrumentation.

Note:
Unless sharing with AVEVA Instrumentation is enabled for the project the checkbox will be disabled. Sharing with AVEVA Instrumentation may be enabled during project setup, or afterwards (using the Project tab > Edit Project option). Refer to the Installation User Guide for details.

Design Data Fields

Additional catalogue data may be entered on this tab to aid design selection.

Outside Diameter

This field is used by Wiring Manager to auto-select cable glands from the Cable Gland Catalogue.

Drum Length

This field is used by Wiring Manager when auto-cable drumming. Wiring Manager will use this value as its default drum length. Refer to Auto-Cable Drumming.

Enhance Cable

Block Diagram

fields

These fields are used to specify the appearance of cables using the cable catalogue in Enhanced Cable Block Diagrams (refer to Create or Edit Content of an Enhanced Cable Block Diagram).

The AutoCAD Export Linetype field list consists of the line types defined in line type seed file selected in the Cable Line Style Reference File (.dwg) field of the Enhanced Cable Block Diagram Options window (Export tab). This list will be empty if no file has been selected.

All other fields are for user reference only and are currently not used for any purpose except reporting.

User Fields

The 30 fields on this tab are used to entered any additional data regarding the catalogue cable as required by the user or project.

Add a New Catalogue Cable

Enter values for all fields in the window, then click Save.

Electrical Wiring Manager will create the cable cores/wires based on the information provided using default core markings. Users can then modify the core markings for this cable by clicking on the View Cores tab. Refer to Change Cable Core Markings.