The following table lists the available object properties in the StatStream object type.

Property

Description

Type

Name

Name of the stream

String

Description

Description

String

StartDateTime

Service start date

String

EndDateTime

Service end date

String

Source

Source object name of the stream

String

Destination

Destination object name of the stream

String

MassFlowrate

Default mass flow rate or calculation equation of flow rate

Numeric or String

VolFlowrate

Default volume flow rate or calculation equation of flow rate

Numeric or String

MinMassRate

Minimum mass flow rate

Numeric

MinVolRate

Minimum volume flow rate

Numeric

MaxMassRate

Maximum mass flow rate

Numeric

MaxVolRate

Maximum volume flow rate

Numeric

MaxVolume

Maximum volume quantity

Numeric

Properties

Property name and its tag or default value with a semicolon separator

String

Components

Component name and its tag or default value with a semicolon separator

String

TagName

Tag name for flow rate measurement

String

ImpUnit

Import engineering unit for flow rate measurement

String

RateUnit

Import rate unit (day, hour) for flow rate measurement

String

ComponentUnit

Import component engineering unit (wt%, vol%)

String

MorU

Measured (M) or Unmeasured (U)

String

FlowType

Type of stream (M (Movement), S (Shipment), R (Receipt))

String

ProdCode

Product code (or name)

String

Phase

Phase status (L (Liquid), G (Gas), S (Solid))

String

MassAbsolute

Absolute tolerance value of mass flow rate

Numeric

VolAbsolute

Absolute tolerance value of volume flow rate

Numeric

MassRelative

Relative tolerance value of mass flow rate

Numeric

VolRelative

Relative tolerance value of volume flow rate

Numeric

Density

Default density

Numeric

MW

Default molecular weight

Numeric

Temperature

Default temperature

Numeric

Pressure

Default pressure

Numeric

bCompensation

Whether to use compensation or not

Boolean

bComponent

Whether to use component data to calculate density and MW or not

Boolean

DensityTag

Density tag name

String

MWTag

MW tag name

String

TemperatureTag

Temperature tag name

String

PressureTag

Pressure tag name

String

AnalyzerTag

Analyzer name

String

KValue

K value for flow compensation

Numeric

FOEValue

Fuel oil equivalent value

Numeric

Model

Model name to which the stream belongs

String

bCalcMassFlowrate

Whether to define the default mass flow rate by equation or not

Boolean

bCalcVolFlowrate

Whether to define the default volume flow rate by equation or not

Boolean

bGS

Whether to select "User Define as Gross Error" or not

Boolean

bNGS

Whether to select "User Define as Not Gross Error" or not

Boolean

bTransaction

Whether the stream is of type transaction or not

Boolean

bActualFlowRate

Whether to include flowrate or not

Boolean

bMassConstraint

Whether to use Min/Max mass constraints or not

Boolean

bVolumeConstraint

Whether to use Min/Max volume constraints or not

Boolean

bLogical

Whether the stream is of type logical or not

Boolean

bLoss

Whether the stream is the receipt or shipment loss stream or not

Boolean

bOS

whether or not the stream is out of service

Boolean

bAbsMassConstraint

Whether to use ± Min/Max mass constraints or not

Boolean

bAbsVolumeConstraint

Whether to use ± Min/Max volume constraints or not

Boolean

Enthalpy

Calculation equation of specific enthalpy if the specific enthalpy calculation method is equation

String

TitleResults for “How to create a CRG?”Also Available in