Triggered.Constant
- Last UpdatedFeb 28, 2025
- 3 minute read
The Debug Information dialog for Triggered.Constant shows TCR streams on all models.
The following procedure describes how to validate a triggered constant stream:
-
Select the DeBug menu.
-
On the DeBug menu, in the Validate Stream group, select Triggered.Constant.
-
Select Yes.
The Debug Information dialog appears displaying a list of all streams with triggered constant values.
-
On the Debug Information dialog, double-click a cell.
The stream information dialog appears. You can view or edit the stream details.
Out of service
If all related streams are out of service, triggered constant stream is set to out of service automatically as well.

And then the solvability of triggered constant stream is changed to TOS (Triggered Out of Service Flow) and the reconciled value is zero.

All TOS streams on the active model are shown at the gross error list as shown below.

Furthermore, all TOS streams on all models are shown in the Validate Triggered Constant Stream window.

If the triggered constant stream is triggered exclusively without relating with other triggered constant streams, the solvability is "TRC1" to distinguish from triggering with other triggered constant streams.
Example
It is very useful to find out the bias factor for the rundown stream with triggered constant to tank and feed stream with triggered constant from tank.

In Case A, the solvability of StreamA and StreamB is "TRC" since the quantity of each stream is not decided by the inventory of TankA.
But in Case B, the solvability of each stream is "TRC1" since the quantify of each stream is decided by the inventory of TankA or TankB and so it is very useful case to find out the bias factor of the stream.
When you click Debug > Triggered.Constant menu, all triggered streams are displayed with the different solvability, calculated bias value and the bias factor as shown below.