Configure export tags for PI
- Last UpdatedNov 10, 2025
- 2 minute read
Configure export tag to export the reconciled value to the PI_EXP_IF interface. You can add a new export tag.
-
Double-click 01FC001 stream.
The stream detail dialog appears.
-
Select Design Info tab.
-
Select the Edit Flow Tag button.
The Edit Tag Information dialog appears.
-
Right-click on No. and select New.
A new export tag is added.
-
Configure the new export tag with the following properties:

Legends:
-
1. Name: Tag name used.
-
2. Type: Tag type. The different types of tag types are F (Flow rate), I (Inventory volume), T (Temperature), P (Pressure) and L (Laboratory).
-
3. Att: Tag attribute. The tag attribute type should be A (Average).
-
4. Interface Name: Interface name. For example, if you select the PI_EXP_IF interface name, the reconciled data is exported to the PI server.
-
5. Tag Name: The actual tag name used in PI.
-
6. Eng. Unit: Engineering unit of reconciled value.
-
-
Select OK.
The newly created export tag is appears in the Tag Name drop-down.

-
Select the Edit Flow Tag button again.
The Edit Tag Information dialog appears.
-
Right-click on No.. and select Export.